dc.date.issued | 2018 | |
dc.identifier.citation | Shapovalov, A. V. Comparative analysis of the efficiency of the operation of vapour dynamic thermosiphone and thermosiphone without inner circulation inserts / A. V. Shapovalov, A. V. Rodin, P. A. Adamenko // Heat pipes, heat pumps, refrigerators, power sources : proceedings of the X Minsk International Seminar Held in Minsk, Belarus, 10-13 September 2018. – Minsk : [s. n.], 2018. – P. 392–395. | ru_RU |
dc.identifier.uri | https://elib.gstu.by/handle/220612/39319 | |
dc.description.abstract | The results of experimental study of the operation of closed loop two phase heat transfer devices i.e.
thermosiphones with an extended zone of evaporation and condensation are presented. The volume of the fluid optimal
for filling the devices is determined, the length distribution of the evaporator and condenser wall temperature
temperatures is obtained. | ru_RU |
dc.language.iso | en | ru_RU |
dc.subject | Thermosiphone | ru_RU |
dc.subject | Vapour dynamic thermosiphone | ru_RU |
dc.subject | Inner circulation inserts | ru_RU |
dc.subject | Thermal resistance | ru_RU |
dc.subject | Evaporation | ru_RU |
dc.subject | Condensation | ru_RU |
dc.title | Comparative analysis of the efficiency of the operation of vapour dynamic thermosiphone and thermosiphone without inner circulation inserts | ru_RU |
dc.type | Article | ru_RU |