Show simple item record

dc.contributor.authorОвсянник, А. В.
dc.contributor.authorКлючинский, В. П.
dc.coverage.spatialМинскru_RU
dc.date.accessioned2021-01-19T09:51:49Z
dc.date.available2021-01-19T09:51:49Z
dc.date.issued2020
dc.identifier.citationОвсянник, А. В. Термодинамический анализ озонобезопасных низкокипящих рабочих тел для турбодетандерных установок / А. В. Овсянник, В. П. Ключинский // Известия высших учебных заведений и энергетических объединений СНГ. Энергетика. – 2020. – Т. 63, № 6. – С. 554–562.ru_RU
dc.identifier.urihttps://elib.gstu.by/handle/220612/23974
dc.description.abstractВ статье рассмотрены 46 низкокипящих рабочих тел (НКРТ), имеющих нулевой потенциал разрушения озонового слоя: 14 однокомпонентных гидрофторуглеродных хладагентов, 28 многокомпонентных смесей гидрофторуглеродных хладагентов и четыре природных хладагента. Произведен термодинамический анализ рабочих тел на базе классической турбодетандерной схемы с теплообменным аппаратом, предназначенным для охлаждения перегретого НКРТ, покинувшего турбодетандер. Для данной схемы построен цикл в T–s-координатах. Сравнение НКРТ производилось по эксергетическому коэффициенту полезного действия (КПД). В ходе исследования выявлено, что для некоторых НКРТ последовательность расположения зависимостей эксергетического КПД от температуры при оптимальных с термодинамической точки зрения давлениях рабочих тел сохраняется на всем изучаемом интервале температур (от 100 до 300 оС). Иными словами, если рабочее тело имеет наибольший эксергетический КПД, то это свойство присуще ему при любой температуре в заданном интервале. Анализ НКРТ по эксергетическому КПД предложено проводить по произвольно выбранной температуре (250 оС). Исследование показало, что наибольшим эксергетическим КПД из природных хладагентов обладает R600A (50,25 %), среди однокомпонентных гидрофторуглеродных хладагентов – R245FA (50,00 %), R1233ZD(E) (49,91 %), R236EA (49,59 %), среди многокомпонентных смесей гидрофторуглеродных хладагентов – R429A (47,92 %), R430A (47,49 %) и R423A (47,47 %). Из всех рассмотренных НКРТ наибольший эксергетический КПД имеют: R600A, R245FA, R1233ZD(E), R236EA, R1234ZE(Z), R236FA. Они принадлежат как к природным хладагентам (углеводороды), так и к однокомпонентным гидрофторуглеродным. Следует отметить, что у каждого из этих рабочих тел есть свои недостатки: одни обладают высоким потенциалом глобального потепления, другие взрывоопасны, третьи имеют высокую стоимость.ru_RU
dc.description.abstractThe article considers 46 low-boiling working media (LBWM) with zero potential for ozone layer destruction. Out of them, 14 ones are single-component hydrofluorocarbon refrigerants, 28 ones are multi-component mixtures of hydrofluorocarbon refrigerants, and the four ones are native refrigerants. Thermodynamic analysis of working media based on the classical turboexpander scheme with a heat exchanger designed to cool the superheated LBWM that has left the turbo-expander has been performed. For this scheme, a cycle is constructed in T–s-coordinates. The LBWM was compared using the exergetic coefficient of efficiency (KE). In the course of the study, it was found that for some LBWM, the sequence of location of the exergetic efficiency dependences on temperature at thermodynamically optimal working medium pressures is preserved over the entire temperature range under study (from 100 to 300 оC). In other words, if the working medium has the highest exergetic efficiency coefficient, then this property is inherent in it at any temperature in a given interval. It is proposed to perform the analysis of the LBWM for exergetic efficiency at an arbitrarily selected temperature (250 оC). The study demonstrated that the highest exergetic efficiency of natural refrigerants is R600A (50.25 %), among singlecomponent hydrofluorocarbon refrigerants – R245FA (50.00 %), R1233ZD(E) (49.91 %), R236EA (49.59 %), among multi-component mixtures of hydrofluorocarbon refrigerants – R429A (47.92 %), R430A (47.49 %) and R423A (47.47 %). Out of the all examined refrigerants, the following ones have the highest exergetic efficiency of all the considered LBWM: R600A, R245FA, R1233ZD(E), R236EA, R1234ZE(Z), R236FA. They belong to both natural refrigerants (hydrocarbons) and single-component hydrofluorocarbons. It should be noted that each of these working media has its drawbacks: some have a high potential for global warming, others are explosive, and others have a high cost.
dc.language.isoruru_RU
dc.publisherБНТУru_RU
dc.subjectТурбодетандерru_RU
dc.subjectФреонru_RU
dc.subjectХладагентru_RU
dc.subjectВторичные энергетические ресурсыru_RU
dc.subjectТепловые отходыru_RU
dc.subjectТермодинамическая эффективностьru_RU
dc.subjectTurbodetanderru_RU
dc.subjectFreonru_RU
dc.subjectRefrigerantsru_RU
dc.subjectSecondary energy resourcesru_RU
dc.subjectThermal wasteru_RU
dc.subjectTthermodynamic efficiencyru_RU
dc.titleТермодинамический анализ озонобезопасных низкокипящих рабочих тел для турбодетандерных установокru_RU
dc.title.alternativeThermodynamic analysis of ozone-safe low boiling working media for turbo-expander plantsru_RU
dc.typeArticleru_RU
dc.identifier.udc658.261:621.56


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record