Снижение недоотпуска электроэнергии и повышение надежности электроснабжения потребителей за счет применения реклоузеров в сельских электрических сетях 10 кВ Гомельского района
dc.contributor.author | Селиверстов, Г. И. | |
dc.contributor.author | Лычев, П. В. | |
dc.contributor.author | Савкова, Т. Н. | |
dc.contributor.author | Дедолко, М. В. | |
dc.contributor.author | Савенок, В. М. | |
dc.contributor.author | Жуковский, А. А. | |
dc.coverage.spatial | Гомель | ru_RU |
dc.date.accessioned | 2025-09-30T10:05:42Z | |
dc.date.available | 2025-09-30T10:05:42Z | |
dc.date.issued | 2025 | |
dc.identifier.citation | Снижение недоотпуска электроэнергии и повышение надежности электроснабжения потребителей за счет применения реклоузеров в сельских электрических сетях 10 кВ Гомельского района / Г. И. Селиверстов, П. В. Лычев, Т. Н. Савкова [и др.] // Вестник Гомельского государственного технического университета имени П. О. Сухого. – 2025. – № 3. – С. 75–81. | ru_RU |
dc.identifier.uri | https://elib.gstu.by/handle/220612/42757 | |
dc.description.abstract | Проанализированы состояние, проблемы и потенциал снижения недоотпуска электроэнергии и повышение надежности электроснабжения потребителей за счет применения реклоузеров в сельских электрических сетях 10 кВ Гомельского района. Приведены варианты места установки реклоузеров: одного реклоузера – при последовательном секционировании линии электропередачи с односторонним питанием и трех реклоузеров – в линии электропередачи с резервированием питания. Определены критерии оптимизации выбора места установки реклоузеров в сети: количество отключений потребителей фидера (линии или участка линии), длительность перерывов электроснабжения потребителей данного фидера, величина недоотпуска электрической энергии потребителям. Установлено, что для варианта установки трех реклоузеров с резервированием питания годовой недоотпуск электроэнергии снижается на 88,6 % по сравнению с базовым вариантом (без установки реклоузеров) и более чем в 3,3 раза, если сравнивать с вариантом установки одного реклоузера на линии электропередачи. | ru_RU |
dc.description.abstract | The article analyzes the status, problems and potential for reducing undersupply of electric power and increasing the reliability of consumer power supply through the use of reclosers in 10 kV rural electric networks of the Gomel region. The article presents options for installing reclosers: one recloser for sequential sectioning of a power transmission line with one-way power supply and three reclosers in a power transmission line with power supply redundancy. The criteria for optimizing the choice of recloser installation location in the network are defined: the number of disconnections of feeder consumers (line or line section), the duration of power supply interruptions for consumers of this feeder, the amount of undersupply of electric power to consumers. It has been established that for the option of installing three reclosers with power supply redundancy, the annual undersupply of electric power is reduced by 88.6% compared to the baseline option (without reclosers installation) and more than 3.3 times when compared to the options for installing one recloser on a power transmission line. | |
dc.language.iso | ru | ru_RU |
dc.publisher | ГГТУ им. П.О. Сухого | ru_RU |
dc.subject | Реклоузер | ru_RU |
dc.subject | Недоотпуск электроэнергии | ru_RU |
dc.subject | Отключения потребителей | ru_RU |
dc.subject | Надежность электроснабжения потребителей | ru_RU |
dc.subject | Recloser | ru_RU |
dc.subject | Undersupply of electricity | ru_RU |
dc.subject | Number of consumer outages | ru_RU |
dc.subject | Duration of consumer outage | ru_RU |
dc.subject | Reliability | ru_RU |
dc.title | Снижение недоотпуска электроэнергии и повышение надежности электроснабжения потребителей за счет применения реклоузеров в сельских электрических сетях 10 кВ Гомельского района | ru_RU |