dc.contributor.author | Hruntovich, N. V. | |
dc.contributor.author | Kapanski, A. A. | |
dc.contributor.author | Baczynski, D. | |
dc.contributor.author | Vagapov, G. V. | |
dc.contributor.author | Fedorov, O. V. | |
dc.coverage.spatial | France | ru_RU |
dc.date.accessioned | 2024-04-03T08:12:59Z | |
dc.date.available | 2024-04-03T08:12:59Z | |
dc.date.issued | 2019 | |
dc.identifier.citation | Optimization of a variable frequency drive pump working on a water tower / N. V. Hruntovich [et al.] // E3S Web of Conferences : 2019 International Scientific and Technical Conference Smart Energy Systems, SES 2019, Kazan, 18–20 september 2019. – Kazan : EDP Sciences, 2019. – Vol. 124. – P. 05060. | ru_RU |
dc.identifier.uri | https://elib.gstu.by/handle/220612/32696 | |
dc.description.abstract | The development of the existing water supply system in towns and villages involves the use of
frequency converters and specialized control algorithms that can maintain the pressure level established in
the supply grid within certain limits. The implementation of the standard scheme includes the elimination of
the water tower, which, on the one hand, reduces the cost of its maintenance. On the other hand, in
emergency situations, the water tower can still supply water to the consumer, which increases the time of
uninterrupted water supply during repairs. The article reveals a method of increasing the energy efficiency
of transporting drinking water with the help of a water tower by eliminating the excessive pressure of the
water rise when using frequency converters. Our research that involved more than 300 pumping stations,
allowed to establish the average value of the excessive pressure of water rise, which reached 0.36 MPa. For
the wells under study, optimization of the pump operation modes revealed the energy-saving potential of up
to 52% due to excessive pressure reduction and up to 2.0% due to a decrease in starting power at the time of
engine acceleration. | ru_RU |
dc.language.iso | en | ru_RU |
dc.publisher | EDP Sciences | ru_RU |
dc.title | Optimization of a variable frequency drive pump working on a water tower | ru_RU |
dc.type | Article | ru_RU |
local.identifier.doi | 10.1051/e3sconf/201912405060 | |