dc.identifier.citation | Ovsyannik, A. V. Thermodynamic analysis and optimization of low-boiling fluid parameters in a turboexpander / A. V. Ovsyannik, V. P. Kliuchinski // Journal of Physics: Conference Series : The Third Conference "Problems of Thermal Physics and Power Engineering", Moscow, 19–23 October 2020. – Moscow, 2020. – Vol. 1683. – P. 042005. | ru_RU |
dc.identifier.uri | https://elib.gstu.by/handle/220612/31464 | |
dc.description.abstract | The influence of the initial parameters of a low-boiling working fluid on the
thermodynamic efficiency for two turbo-expander cycles (with a heat exchanger at the outlet of
the turbo-expander and without a heat exchanger) is considered. For each of the studied cycles,
the dependences of the exergy efficiency on the temperature of the low-boiling working fluid
before the turboexpander at a constant pressure and the dependence of the exergetic efficiency
on the pressure of the low-boiling working fluid before the turbo-expander at a constant
temperature were obtained. The dependences of exergy losses on the elements of the studied
cycles on the parameters of a low-boiling working fluid are constructed and their analysis is
carried out. For the considered schemes, the dependences of the exergy efficiency on pressure
are constructed at various temperatures of the low-boiling working fluid in front of the
turboexpander. An analysis of the results showed that at any temperature of a low-boiling
working fluid, it is possible to determine the pressure at which the exergy efficiency of the
investigated circuit will be maximum. Graphic dependencies are obtained that are
characterized, from a thermodynamic point of view, by the optimal parameters of a low-boiling
working fluid. Comparison of these dependences revealed that, over the entire range of studied
temperatures (from 100 °C to 300 °C), a cycle with a heat exchanger at the outlet of the
turboexpander has a large exergy efficiency. These graphical dependencies make it possible to
determine the optimal parameters of the working fluid in the turboexpander cycle, as well as to
predict the change in the exergy efficiency of the installation with changing parameters of the
working fluid. | ru_RU |