dc.identifier.citation | Овсянник, А. В. Экспериментальное исследование теплообмена при конденсации смесевых хладагентов и их маслофреоновых смесей на горизонтальных теплообменных поверхностях / А. В. Овсянник, В. П. Ключинский, В. П. Никитенко // Вестник Гомельского государственного технического университета имени П. О. Сухого : научно-практический журнал. – 2023. – № 3.— С. 58-66. | ru_RU |
dc.identifier.uri | https://elib.gstu.by/handle/220612/28917 | |
dc.description.abstract | Разработана методика проведения экспериментального исследования конденсации фреонов
(R404A, R407C и R410A) и их маслофреоновых смесей на гладких и развитых горизонтальных поверхностях. В качестве исследуемой поверхности теплообмена выступала гладкая и продольно оребренная поверхность с трапециевидной формой ребра. В результате экспериментальных исследований
определены температуры основной поверхности и ребра в основании, в середине и на вершине, фиксируемые термопарами при различных плотностях тепловых потоков и концентрациях масла при
исследовании маслофреоновых смесей. Для анализа полученных результатов разработана методика
определения коэффициентов теплоотдачи при конденсации указанных фреонов. В результате проведенных исследований получены значения коэффициентов теплоотдачи при конденсации паров чистых смесевых хладагентов и их маслофреоновых смесей с концентрацией масла 0, 5 и 10 % на гладких и оребренных поверхностях. Полученные результаты свидетельствуют о влиянии концентрации
масла на коэффициент теплоотдачи при различных значениях плотности теплового потока. | ru_RU |
dc.description.abstract | A methodology was developed for conducting an experimental research of the condensation of freons
(R404A, R407C and R410A) and their oil-rheon mixtures on smooth and developed horizontal surfaces.
A smooth and longitudinally finned surface with a trapezoidal rib shape acted as the studied heat exchange
surface. As a result of experimental research, the temperatures of the main surface and ribs at the base,
in the middle and at the apex, fixed by thermocouples at different densities of heat flows and oil
concentrations during the research of oil-rheon mixtures, were determined. To analyze the obtained results,
a method for determining heat transfer coefficients during condensation of these freons was developed.
As a result of research, values of heat transfer coefficients are obtained during condensation of vapors
of pure mixed refrigerants and their oil-rheon mixtures with oil concentration of 0, 5 and 10 % on smooth
and finned surfaces. The results show the effect of oil concentration on heat transfer coefficient at different
values of heat flux density. | |
dc.language.iso | ru | ru_RU |
dc.publisher | ГГТУ им. П.О. Сухого | ru_RU |
dc.subject | Конденсация | ru_RU |
dc.subject | Хладагент | ru_RU |
dc.subject | Коэффициент теплоотдачи | ru_RU |
dc.subject | Фреон | ru_RU |
dc.subject | Экспериментальная установка | ru_RU |
dc.subject | Методика | ru_RU |
dc.subject | Маслофреоновая смесь | ru_RU |
dc.subject | Condensation | ru_RU |
dc.subject | Refrigerant | ru_RU |
dc.subject | Heat transfer coefficient | ru_RU |
dc.subject | Freon | ru_RU |
dc.subject | Experimental plant | ru_RU |
dc.subject | Procedure | ru_RU |
dc.subject | Oil- freon mixture | ru_RU |
dc.title | Экспериментальное исследование теплообмена при конденсации смесевых хладагентов и их маслофреоновых смесей на горизонтальных теплообменных поверхностях | ru_RU |
dc.title.alternative | Experimental research of heat exchange during condensation of mixed refrigerants and their oil-freon mixtures on horizontal heat exchange surfaces | ru_RU |
dc.type | Article | ru_RU |
dc.identifier.udc | 658.261:621.56 | |