<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:dc="http://purl.org/dc/elements/1.1/" version="2.0">
<channel>
<title>№2</title>
<link>https://elib.gstu.by/handle/220612/16816</link>
<description/>
<pubDate>Fri, 17 Apr 2026 15:03:18 GMT</pubDate>
<dc:date>2026-04-17T15:03:18Z</dc:date>
<item>
<title>Интеграционные процессы и славянская ментальность</title>
<link>https://elib.gstu.by/handle/220612/18178</link>
<pubDate>Thu, 07 Dec 2017 08:33:13 GMT</pubDate>
<guid isPermaLink="false">https://elib.gstu.by/handle/220612/18178</guid>
<dc:date>2017-12-07T08:33:13Z</dc:date>
<dc:creator>Кириенко, В. В.</dc:creator>
<dc:creator>Савенко, А. Ю.</dc:creator>
</item>
<item>
<title>Теоретические аспекты построения и содержание механизма антикризисного управления телекоммуникационных предприятий Украины</title>
<link>https://elib.gstu.by/handle/220612/16832</link>
<pubDate>Fri, 14 Jul 2017 11:13:54 GMT</pubDate>
<guid isPermaLink="false">https://elib.gstu.by/handle/220612/16832</guid>
<dc:date>2017-07-14T11:13:54Z</dc:date>
<dc:creator>Гудзь, Е. Е.</dc:creator>
<dc:creator>Старинец, А. Г.</dc:creator>
<dc:description>Рассмотрены теоретические, методологические и практические аспекты формирования и функционирования механизма антикризисного управления предприятий, выявлены проблемы и предложен профиль механизма антикризисного управления телекоммуникационных предприятий на основе учета причинно-следственных связей между отдельными его составляющими и интересов заинтересованных сторон, выявления скрытых ресурсов, формирования более гибкой и чувствительной организационной структуры, способной своевременно реагировать на изменения и вызовы, а также обоснована система критериев и индикаторов эффективности антикризисного управления предприятием, которые будут своевременно сигнализировать о симптомах кризисных явлений и процессов.

Theoretical, methodologic and practical aspects of the formation and functioning of the mechanism of enterprises crisis management are considered, the problems are defined and the profile of the mechanism of crisis management of telecommunication enterprises is proposed based on allowing for cause-effect relation between some of its components and stakeholders’ interests, revealing latent resources, the formation of more flexible and sen­sitive organizational structure capable to timely respond to the changes and challenges and also the system of criteria and indicators of the efficiency of enterprises crisis management is justi­fied which will timely give warning of the symptoms of crisis phenomena and processes.</dc:description>
</item>
<item>
<title>Определение энергетической эффективности электрооборудования нетяговых железнодорожных потребителей с помощью имитационного моделирования при проектировании</title>
<link>https://elib.gstu.by/handle/220612/16831</link>
<pubDate>Fri, 14 Jul 2017 10:42:25 GMT</pubDate>
<guid isPermaLink="false">https://elib.gstu.by/handle/220612/16831</guid>
<dc:date>2017-07-14T10:42:25Z</dc:date>
<dc:creator>Дробов, А. В.</dc:creator>
<dc:creator>Галушко, В. Н.</dc:creator>
<dc:creator>Алферов, А. А.</dc:creator>
<dc:creator>Алферова, Т. В.</dc:creator>
<dc:description>Разработаны две имитационные модели для выбора оптимального электроснабжения нетяговых железнодорожных потребителей: одна из которых (имитационная модель узлов) позволяет определить наиболее эффективные варианты организации электроснабжения нетяговых потребителей железнодорожного транспорта с наименьшими приведенными затратами с использованием матрицы возможных электрических связей между трансформаторными подстанциями; другая (имитационная модель продольного электроснабжения) может быть использована для поиска варианта организации электроснабжения с наименьшей величиной технологического расхода электроэнергии на транспортировку по методу статистических испытаний на основании рационального подбора оборудования. Предлагаемые модели могут быть использованы для выбора оптимального числа и мощности трансформаторов, сечений кабельных и воздушных линий.

Two simulation models are developed for the selection of an optimal electric power supply of non-traction railroad consumers: one of which (simulation model of nodes) enables to determine most efficient variants of the organization of electric power supply of railroad transport non-traction consumers with the lowest reduced cost with the use of the matrix of possible electric coupling between transformer substations. The other model (simulation model of longitudinal electric power supply) can be used to find a variant of organization of electric power supply with the lowest technological electric power consumption for transportation by the method of statistical tests based on efficient selection of equipment. The models proposed can be used for the selection of optimal number and power of transformers and the sections of cable and overhead transmission lines.</dc:description>
</item>
<item>
<title>Выбор мест установки пунктов автоматического секционирования в распределительных электрических сетях сельскохозяйственного назначения</title>
<link>https://elib.gstu.by/handle/220612/16830</link>
<pubDate>Fri, 14 Jul 2017 10:35:45 GMT</pubDate>
<guid isPermaLink="false">https://elib.gstu.by/handle/220612/16830</guid>
<dc:date>2017-07-14T10:35:45Z</dc:date>
<dc:creator>Пухальская, О. Ю.</dc:creator>
<dc:creator>Медведев, К. М.</dc:creator>
<dc:creator>Линбинь, Дэн</dc:creator>
<dc:description>Изучено влияние мест установки пунктов автоматического секционирования на количество отключений и время восстановления ВЛ 10 кВ сельскохозяйственного назначения. Исследования проводились на модели ВЛ 10 кВ с двумя реклоузерами: один установлен в качестве пункта автоматического секционирования, второй – в качестве пункта автоматического ввода резерва в точке нормального токораздела.&#13;
Построены зависимости степени снижения количества отключений и времени отключения ВЛ от места установки реклоузера, которые позволяют выбрать оптимальное место установки пункта автоматического секционирования с учетом требований к уровню надежности электроснабжения потребителей.&#13;
Показано, что максимальное снижение количества отключений и времени отключения ВЛ наблюдается при установке реклоузера в середине линии.

The influence of the location of automatic sectionalization points on the number of interruptions and restoration time for 10 kV rural high-voltage lines is studied. The study was car­ried out on the model of 10 kV high-voltage lines with two reclosers: one of them is installed as the automatic sectionalization point and the other one is located in the normally open point as an automatic load transfer point.&#13;
The dependencies of the degree of reducing the number of interruptions and the time of high-voltage line de-energization on the location of the recloser are built which enables to select an optimal location of the automatic sectionalization point allowing for the requirements of consumers’ electric power supply reliability.&#13;
It is shown that maximum reduction of the number of interruptions and the time of high-voltage line de-energization is observed when locating the recloser in the midpoint of the line.</dc:description>
</item>
<item>
<title>Условия работы электрической изоляции фланцевых соединений газопроводов природного газа при аварийных режимах работы системы катодной защиты</title>
<link>https://elib.gstu.by/handle/220612/16829</link>
<pubDate>Fri, 14 Jul 2017 10:29:49 GMT</pubDate>
<guid isPermaLink="false">https://elib.gstu.by/handle/220612/16829</guid>
<dc:date>2017-07-14T10:29:49Z</dc:date>
<dc:creator>Рудченко, Ю. А.</dc:creator>
<dc:creator>Зализный, Д. И.</dc:creator>
<dc:description>Разработана электрическая схема замещения газопровода, позволяющая рассчитывать разность потенциалов на изоляции фланцевого соединения между ответвлением от радиального распределительного подземного газопровода низкого давления и газопроводом, соединенным с газовыми приборами потребителя. В схеме учтены активное, индуктивное и емкостное сопротивления газопровода. На основе проведенных расчетов показано, что наибольшие перенапряжения на фланцевом соединении, способные при-вести к пробою его изоляции и последующему воспламенению газа, обусловлены аварийной работой системы катодной защиты газопровода.

Electrical equivalent circuit of the gas pipeline enabling to calculate potential difference on the insulation of the flange coupling between the service pipe of radial distribution underground low pressure gas pipeline and the gas pipeline connected with gas devices of the con­sumer. Active resistance, inductive reactance and capacitance of the gas pipeline are allowed for in this circuit. Based on the calculations performed it is shown that the highest overvoltage on the flange coupling which can lead to insulation breakdown and the following gas inflam­mation is conditioned by emergency operation of the gas pipeline cathodic protection system.</dc:description>
</item>
<item>
<title>Локально-неравновесные свойства фазовой границы высокоскоростной кристаллизации переохлажденного расплава Часть 1. Трансзвуковой переход на линии роста</title>
<link>https://elib.gstu.by/handle/220612/16828</link>
<pubDate>Fri, 14 Jul 2017 07:36:16 GMT</pubDate>
<guid isPermaLink="false">https://elib.gstu.by/handle/220612/16828</guid>
<dc:date>2017-07-14T07:36:16Z</dc:date>
<dc:creator>Шабловский, О. Н.</dc:creator>
<dc:creator>Кроль, Д. Г.</dc:creator>
<dc:creator>Концевой, И. А.</dc:creator>
<dc:description>Для фазовой границы стационарной формы получены аналитические выражения, позволяющие определить производные от температуры и компонент вектора теплового потока в касательном и нормальном к фазовой границе направлениях. Математической моделью предвестника боковой ветви дендрита на фазовой границе служит появление звуковой точки: именно в этом состоянии начинается разрушение теплового поля. Показано, что время тепловой релаксации является параметром регуляризации поведения касательной компоненты теплового потока. Дан пример расчета высокоскоростного затвердевания переохлажденного расплава никеля. Приведена подробная графическая информация о градиентных свойствах температуры и тепловых потоков.

Phase boundaries of stationary shape are described with analytical expressions defining normal and tangential derivatives of the temperature and heat flux vector components. The forerunner of the lateral branch of the dendrite on the phase boundary is modeled by arising the sonic point since it’s the state from which the thermal field starts collapsing. It’s shown that the thermal relaxation time is a regularizing parameter for the behaviour of the tangential com­ponent of the heat flux. An example for calculating the high-speed solidification of the over-cooled nickel melt is given. Detailed graphic information on the gradient properties of tem­perature and heat fluxes is given.</dc:description>
</item>
<item>
<title>Определение величины критической упругой остаточной деформации при плакировании порошковыми покрытиями (Обзор)</title>
<link>https://elib.gstu.by/handle/220612/16827</link>
<pubDate>Fri, 14 Jul 2017 07:24:26 GMT</pubDate>
<guid isPermaLink="false">https://elib.gstu.by/handle/220612/16827</guid>
<dc:date>2017-07-14T07:24:26Z</dc:date>
<dc:creator>Урбанович, А. М.</dc:creator>
<dc:creator>Бобарикин, Ю. Л.</dc:creator>
<dc:creator>Шишков, С. В.</dc:creator>
<dc:description>Представлен анализ процесса плакирования порошковыми покрытиями металлической основы совместной пластической деформацией.&#13;
На основе представленного анализа можно утверждать, что релаксационные явления оказывают важнейшее влияние на схватывание твердых металлических тел при плакировании.&#13;
В этой связи представляется актуальным изучение релаксационных процессов в зоне образования соединения между плакирующим слоем и основой. Определение закономерностей их протекания будет способствовать рациональному планированию режимов обработки, обеспечивающих качественное соединение и, как следствие, будет обеспечивать достаточные эксплуатационные свойства получаемых слоистых материалов.

The analysis of the process of powder plating of the metal base by a combined plastic deformation is presented.&#13;
Based on the analysis presented it can be stated that relaxation phenomena have great influence on the seizure of solid metal bodies during plating.&#13;
In this connection it seems timely to study relaxation processes in the zone of formation of bond between a plating layer and the base. Defining the regularities of their behavior will facilitate rational planning of working conditions ensuring high quality bond and consequently will ensure sufficient operational characteristics of the layered materials obtained.</dc:description>
</item>
</channel>
</rss>
